| 1874 - 1098 pages
...double-riveted with rivets having an allowance of not more than fifty per cent, over tho single shear, and provided that the boilers have been open to inspection during the whole period of construction, then six may be used as the factor of safety. But the boilers must be tested by hydraulic pressure to twice... | |
| William Miller Barr - 1879 - 490 pages
...double-riveted with rivets having an allowance of not more than fifty per cent over the single shear, and provided that the boilers have been open to inspection during the whole period of construction, then six may be used as the factor of safety. But the boilers must be tested by hydraulic pressure to twice... | |
| Clement Mackrow - 1879 - 552 pages
...double-riveted with rivets having an allowance of not more than 50 per cent, over the single shear, and provided that the boilers have been open to inspection during the whole period of construction, then 6 may be used as the factor of safety; but the boilers must be tested by hydraulic pressure to twice... | |
| Royal Institution of Naval Architects - 1883 - 406 pages
...double riveted, with rivets having an allowance of not more than 75 per cent, over single sheer, and provided that the boilers have been open to inspection during the whole period of construction, then 5 may be used as the factor of safety. The tensile strength of the iron is to be taken as equal to... | |
| 1884 - 270 pages
...double riveted, with rivets having an allowance of not more than 75 per cent, over single sheer, and provided that the boilers have been open to inspection during the whole period of con. struction, then 5 may be used as the factor of safety. The tensile strength of the iron is to... | |
| Charles Augustus Smith - 1885 - 226 pages
...double rivetted with rivets having an allowance of not more than 75 per cent, over single shear, and provided that the boilers have been open to inspection during the whole period of construction, then 5 may be used as the factor of safety. The tensile strength of the iron is to be taken as equal to... | |
| Richard Sennett - 1885 - 750 pages
...double riveted with rivets having an allowance of not more than 75 per cent, over the single shear, and provided that the boilers have been open to inspection during the whole period of construction, then 5 may be used as the factor of safety. The tensile strength of the iron is to be taken as equal to... | |
| Albert Edward Seaton - 1886 - 520 pages
...double-riveted with rivets having an allowance of not more than 75 per cent. over the single shear, and provided that the boilers have been open to inspection during the whole period of construction, then 5 may be used as the factor of safety. The tensile strength of the iron is to be taken as equal to... | |
| Bindon Blood Stoney - 1886 - 842 pages
...double riveted with rivets having an allowance of not more than 75 per cent, over the single shear, and provided that the boilers have been open to inspection during the whole period of construction, then 5 may be used as the factor of safety. The tensile strength of the iron is to be taken as equal to... | |
| Albert Edward Seaton - 1886 - 514 pages
...double-riveted with rivets having an allowance of not more than 75 per cent. over the single shear, and provided that the boilers have been open to inspection during the whole period of construction, then 5 may be used as the factor of safety. The tensile strength of the iron is to be taken as equal to... | |
| |